Grayline 105°C is a flexible polyvinyl chloride tubing designed for a wide range of electrical tubing and electrical insulating applications. This flame resistant product features a wide operating temperature range, and outstanding physical and electrical insulating properties. It is typically used as a wiring harness covering, or as a terminal and splice insulation where low cost, mechanical toughness and flame resistance are important considerations.
|
105°C |
Features |
|
|
|
Specifications |
|
|
|
Ordering Information |
|
|
|
*optional |
|
| PROPERTY | TYPICAL VALUE | TEST METHOD |
| Durometer Shore A/C (10 Seconds) | 88/62 Colors 94/69 Clear |
ASTM D2240 |
| Tensile Strength (psi) | 2,500 | ASTM D412 |
| Elongation (%) | 280 | ASTM D412 |
| Specific Gravity +/-.02 | 1.37 Colors 1.25 Clear |
ASTM D792 |
| Flammability | VW-1 | UL 224 |
| Brittleness Temperature, Pass °C | -28 Colors -23 Clear |
ASTM D746 |
| Heat Aging, 7 days @ 136°C % of Original Tensile Strength % of Original Elongation |
102 82 |
UL 224 |
| Copper Corrosion | None | UL 224 |
| Longitudinal Shrinkage, 2 Hrs @ 100°C | Less than 5% | UL 224 |
| Dielectric Strength (Volts/Mil, .031") | 800 | UL224 |
| Volume Resistivity (ohm-cm) | 1011 | ASTM D257 |
| Low Temperature Flexibility, 30°C | Pass | UL 224 |
The values listed in this bulletin, to the best of our knowledge, are accurate. They are typical performance results and are not intended to be used as design data. We disclaim all liability in connection with the use of information contained herein or otherwise.