Heat Shrinkable Tubing

Home >> Wire Harness / Electrical Tubing / Heat Shrink >> Heat Shrinkable Tubing

Wire harness with heat-shrink tubing

Heat shrinkable tubing is used in wire harnesses and other electrical applications to bundle, insulate, and protect wires and electrical components. After placing heat shrinkable tubing over an object to be covered, heat is applied to cause the tubing to shrink in size and conform tightly to the object.

Grayline offers a wide range of heat shrinkable tubing products having shrink ratios of 2:1, 3:1 and 4:1, including adhesive lined (dual wall) products to provide the ultimate environmental seal.

To learn more about heat shrinkable tubing, please click on any of the following links:

Material Type: Polyvinyl Chloride (PVC)
Name Shrink Ratio Material Characteristics Adhesive Lined Available Colors Operating Temp °C Agency Ratings &
Material Specifications
HS-105C 2:1
Non-DEHP PVC
No
Natural (Opaque)
White
Yellow
Orange
Red
Gray
Green
Purple
Blue
Brown
Black
Clear
Other
-30° to 105°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 105°C, 600V
UL/CSA VW1

FMVSS302

 

Material Type: Polyolefin
Name Shrink Ratio Material Characteristics Adhesive Lined Available Colors Operating Temp °C Agency Ratings &
Material Specifications
GP125 2:1
Chemically Cross-linked
Fungus Resistant
No
Black
Clear
Other
-55° to 125°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
 
SL2535 2:1
Fungus Resistant
No
White
Yellow
Red
Blue
Black
-55° to 135°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V

SAE AS23053/5, Class 1
SL2535CL 2:1
Fungus Resistant
No
Clear
-55° to 135°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)

SAE AS23053/5, Class 2
SL125 2:1
Fungus Resistant
No
White
Yellow
Red
Blue
Black
-55° to 135°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V
UL/CSA VW1

SAE AS23053/5, Class 1
SAE AS23053/5, Class 3
FMVSS302
SL3X 3:1
Fungus Resistant
No
White
Yellow
Red
Blue
Black
-55° to 135°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V
UL/CSA VW1

SAE AS23053/5, Class 1 & 3
FMVSS302
TI 2.5:1
Fungus Resistant
No
Black
-55° to 135°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)

MIL-DTL-23053/6, Class 1 or SAE-AMS-DTL-23053/6, Class 1
BD275 2:1
Fungus Resistant
No
White
Black
-55° to 135°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
 
AL2X 2:1
Fungus Resistant
Yes
Black
-55° to 110°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V

SAE AS23053/4 Class 2
AL3X 3:1
Fungus Resistant
Yes
White
Black
-55° to 110°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V

SAE AS23053/4 Class 3
AL4X 4:1
Fungus Resistant
Yes
Black
-55° to 110°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V
 
MWT 3:1
Fungus Resistant
Yes
Red
Black
Clear
-55° to 110°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
 
HWT 3:1
Fungus Resistant
Yes
Red
Black
-55° to 110°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)

ANSI C119-1
Western Underground Guide 2.4, 2.5
HWT-FR 3:1
Fungus Resistant
Yes
Red
Black
-55° to 110°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)

MIL-DTL-23053/15, Class 1 or SAE-AMS-DTL-23053/15, Class 1
ANSI C119-1
Western Underground Guide 2.4, 2.5
IEEE 383 Vertical Flame Test
ALAS-130 4:1
Fungus Resistant
Yes
Black
-40° to 130°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
 
ALAS-125 4:1
Fungus Resistant
Yes
Black
Clear
-55° to 125°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
 
DW4X 4:1
Fungus Resistant
Yes
Red
Black
-55° to 135°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)

SAE AS23053/4 Class 3
ML251 2.5:1
Fungus Resistant
Yes
Black
-55° to 110°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)

SAE AS23053/4 Class 1
NHS 2:1
Fungus Resistant
No
Black
-75° to 120°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)

SAE AS23053/1 Class 1
SAE AS23053/1 Class 2

 

Material Type: Modified Fluoroelastomer
Name Shrink Ratio Material Characteristics Adhesive Lined Available Colors Operating Temp °C Agency Ratings &
Material Specifications
MF392 2:1
Fungus Resistant
No
Black
-40° to 200°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)

SAE AS23053/13
NASA SP-R-022A (Outgassing)

 

Material Type: PVDF
Name Shrink Ratio Material Characteristics Adhesive Lined Available Colors Operating Temp °C Agency Ratings &
Material Specifications
PVDF 2:1
Fungus Resistant
No
Clear
-55° to 175°
EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 150°C, 600V
UL/CSA VW1

SAE AS23053/8
FMVSS302

 

(Kynar® is a registered trademark of Arkema, Inc.)



Not sure which tubing you need? Click here to try our tubing selection guide.Prefer to speak with a technical sales representative?
Click here to email us or
phone Grayline at 1-800-669-7986