Heat Shrinkable Tubing
Home >> Wire Harness / Electrical Tubing / Heat Shrink >> Heat Shrinkable Tubing

Heat shrinkable tubing is used in wire harnesses and other electrical applications to bundle, insulate, and protect wires and electrical components. After placing heat shrinkable tubing over an object to be covered, heat is applied to cause the tubing to shrink in size and conform tightly to the object.
Grayline offers a wide range of heat shrinkable tubing products having shrink ratios of 2:1, 3:1 and 4:1, including adhesive lined (dual wall) products to provide the ultimate environmental seal.
To learn more about heat shrinkable tubing, please click on any of the following links:
- Making Extruded Tubing Heat Shrinkable
- Shrink Ratio
- Longitudinal Shrinkage
- Inside Diameter and Wall Thickness
- PVC vs. Polyolefin Heat Shrinkable Tubing
- Available Colors
- Adhesive lined (Dual Wall) Heat Shrinkable Tubing
- Printing and Hot Stamping
- Electrical and Wiring Harness Applications
- Non-Electrical Applications
- Storage and Shelf Life
Material Type: Polyvinyl Chloride (PVC) | ||||||
---|---|---|---|---|---|---|
Name | Shrink Ratio | Material Characteristics | Adhesive Lined | Available Colors | Operating Temp °C | Agency Ratings & Material Specifications |
HS-105C | 2:1 | Non-DEHP PVC
|
No | Natural (Opaque)
White
Yellow
Orange
Red
Gray
Green
Purple
Blue
Brown
Black
Clear
Other
|
-30° to 105° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 105°C, 600V
UL/CSA VW1
FMVSS302 |
Material Type: Polyolefin | ||||||
---|---|---|---|---|---|---|
Name | Shrink Ratio | Material Characteristics | Adhesive Lined | Available Colors | Operating Temp °C | Agency Ratings & Material Specifications |
GP125 | 2:1 | Chemically Cross-linked
Fungus Resistant
|
No | Black
Clear
Other
|
-55° to 125° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
|
SL2535 | 2:1 | Fungus Resistant
|
No | White
Yellow
Red
Blue
Black
|
-55° to 135° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V
SAE AS23053/5, Class 1 |
SL2535CL | 2:1 | Fungus Resistant
|
No | Clear
|
-55° to 135° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
SAE AS23053/5, Class 2 |
SL125 | 2:1 | Fungus Resistant
|
No | White
Yellow
Red
Blue
Black
|
-55° to 135° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V
UL/CSA VW1
SAE AS23053/5, Class 1
SAE AS23053/5, Class 3
FMVSS302 |
SL3X | 3:1 | Fungus Resistant
|
No | White
Yellow
Red
Blue
Black
|
-55° to 135° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V
UL/CSA VW1
SAE AS23053/5, Class 1 & 3
FMVSS302 |
TI | 2.5:1 | Fungus Resistant
|
No | Black
|
-55° to 135° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
MIL-DTL-23053/6, Class 1 or SAE-AMS-DTL-23053/6, Class 1 |
BD275 | 2:1 | Fungus Resistant
|
No | White
Black
|
-55° to 135° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
|
AL2X | 2:1 | Fungus Resistant
|
Yes | Black
|
-55° to 110° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V
SAE AS23053/4 Class 2 |
AL3X | 3:1 | Fungus Resistant
|
Yes | White
Black
|
-55° to 110° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V
SAE AS23053/4 Class 3 |
AL4X | 4:1 | Fungus Resistant
|
Yes | Black
|
-55° to 110° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 125°C, 600V
|
MWT | 3:1 | Fungus Resistant
|
Yes | Red
Black
Clear
|
-55° to 110° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
|
HWT | 3:1 | Fungus Resistant
|
Yes | Red
Black
|
-55° to 110° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
ANSI C119-1
Western Underground Guide 2.4, 2.5 |
HWT-FR | 3:1 | Fungus Resistant
|
Yes | Red
Black
|
-55° to 110° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
MIL-DTL-23053/15, Class 1 or SAE-AMS-DTL-23053/15, Class 1
ANSI C119-1
Western Underground Guide 2.4, 2.5
IEEE 383 Vertical Flame Test |
ALAS-130 | 4:1 | Fungus Resistant
|
Yes | Black
|
-40° to 130° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
|
ALAS-125 | 4:1 | Fungus Resistant
|
Yes | Black
Clear
|
-55° to 125° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
|
DW4X | 4:1 | Fungus Resistant
|
Yes | Red
Black
|
-55° to 135° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
SAE AS23053/4 Class 3 |
ML251 | 2.5:1 | Fungus Resistant
|
Yes | Black
|
-55° to 110° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
SAE AS23053/4 Class 1 |
NHS | 2:1 | Fungus Resistant
|
No | Black
|
-75° to 120° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
SAE AS23053/1 Class 1
SAE AS23053/1 Class 2 |
Material Type: Modified Fluoroelastomer | ||||||
---|---|---|---|---|---|---|
Name | Shrink Ratio | Material Characteristics | Adhesive Lined | Available Colors | Operating Temp °C | Agency Ratings & Material Specifications |
MF392 | 2:1 | Fungus Resistant
|
No | Black
|
-40° to 200° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
SAE AS23053/13
NASA SP-R-022A (Outgassing) |
Material Type: PVDF | ||||||
---|---|---|---|---|---|---|
Name | Shrink Ratio | Material Characteristics | Adhesive Lined | Available Colors | Operating Temp °C | Agency Ratings & Material Specifications |
PVDF | 2:1 | Fungus Resistant
|
No | Clear
|
-55° to 175° | EU Directive 2000 / 53 / EC (ELV)
EU Directive 2011 / 65 / EU (RoHS2)
EU Directive 2015 / 863 (RoHS3)
UL/CSA: 150°C, 600V
UL/CSA VW1
SAE AS23053/8
FMVSS302 |
(Kynar® is a registered trademark of Arkema, Inc.)
Prefer to speak with a technical sales representative?
Click here to email us or
phone Grayline at 1-800-669-7986